Experimental energy performance evaluation in a commercial freezer using R1234yf at different thermal load levels

Main Article Content

Vicente Pérez García
Darío Méndez Méndez
Óscar Adrián Guzmán Guerrero

Abstract

The use of low GWP refrigerants has been extended around of world due to new environmental policies in the last decade. In this sense, commercial refrigerants that are replacing R134a have a principal characteristic of a low global warming potential (GWP). This paper presents an experimental study of energy performance on a commercial freezer using R1234yf as a replacement to R134a considering three thermal load conditions: without thermal load, medium load thermal load, and full thermal load. Results showed that the use of R1234yf promotes a reduction in the internal temperature on the freezer which is 2.3% lowest cold R134a, while the steady thermal time gets with R134a is lower than R1234yf in 11.1%, 11.7%, and 4.4% respectively for each thermal load level.

Article Details

Section

Articulos

Author Biographies

Vicente Pérez García, , ,

División de ingenierías Campus Irapuato Salamanca, Universidad de Guanajuato, INASE Research Group.

Darío Méndez Méndez, , ,

División de ingenierías Campus Irapuato Salamanca, Universidad de Guanajuato, INASE Research Group.

Óscar Adrián Guzmán Guerrero, , ,

División de ingenierías Campus Irapuato Salamanca, Universidad de Guanajuato, INASE Research Group.

 

How to Cite

Experimental energy performance evaluation in a commercial freezer using R1234yf at different thermal load levels. (2021). Ingenio Magno, 12(1), 52-65. https://revistas.santototunja.edu.co/index.php/ingeniomagno/article/view/2309